This program converts text files exported out
of Design Data using their Bill Interchange Format File (BIF File)
into the proper format for importation into EJE's Material Manager
software.
The program consist of several windows shown in Figures below, including a registration
form. A short description of each window/screen and its function in the program
follows the figure. |
Registration Window

Figure 1 - Registration Window
When you start the application for the first time, the Registration
Form will appear. If you are running this application in the "Demo" mode,
enter your Name and Company Name in the fields provided. Enter the
word DEMO in both the Serial Number
and Password fields. This will allow the program to run in a Demo
mode for up to 30 days. In this mode, only the first drawing in the
BIF file will be converted into an E.J.E. compatible format.
If you have purchased the package, you will be issued a Serial Number
and Password and only a Splash screen will appear when you start
the application. |
Main Conversion Window

Figure 2 - Main Conversion Window
The screen shown in Figure 2 is the main screen that appears when
the Bif2Eje.Exe program is executed. The screen consists of two input
fields and four sets of options. Each of the input fields and the
options are described below. |
Input Field Descriptions |
| |
Input File Field
The Input File field is where you would specify the location of the BIF file
that was exported from Design Data. This is the file that you wish to convert
into an E.J.E. compatible file. The following window will appear if you click
on the Browse button beside the Input File field. Locate your BIF file and
double click on the file name or highlight the file and click on the Open push
button.

Figure 3 - Open Input BIF File Window
Output Field
The Output field is where you would specify the name of the
text file that will be created after the conversion process has been
completed. If the output file already exist when you click on the
Convert or Delimited button, you will be prompted to Append, Overwrite
or Cancel the conversion process. The following window will appear
if you click on the Browse button beside the Output File field. Locate
where you would like to place the converted data and specify its
name in the File Name field and click on the Save push button.

Figure 4 - Output File Window
If the output file already exist when you click on the Convert or Delimited
button, the following window will appear. You should then specify if you
wish to Append, Overwrite or Cancel the conversion process.

Figure 5 - Existing File Message Window
|
Option Descriptions |
| |
Piece Mark Case Option
This option is used to keep the existing case structure of the piece marks in
the BIF file or to convert all piece marks between Main Members to lower case
characters or between Major Piece Marks (first piece under the Main Member description),
if the Main Member lines are discarded.
Main Member Option
This option is used to keep or discard the Main Member lines
in the BIF file. If the Main Member lines are discarded, "MM" material
types will not exist in the EJE import file.
Sequence Information Option
This option is used to place sequence information
in the remarks field or create separate lines in the EJE
import
file. If the sequence information is placed in the remarks
field, the code will appear as <Qty>s<Seq #>.
Sequence information in remarks example (quantity of 4 in
sequence one):
2C2 4 TS 80 80 4 3263 A500 M1E B1E
A500B*4s1
Separate lines for each sequence quantity (quantity of
4 in sequence one):
2C2 4 TS 80 80 4 3263 A500 M1E B1E
A500B 1 |
Push Button Descriptions |
| |
Keep Main Member Remarks
This option is used to keep or discard the remarks that appear
with the Main Member lines in the BIF file. In the EJE import file,
Main Members do not have the capability of having remarks. If you wish
to keep the remark information that appears in the Bill of Material,
select the "Keep" option and specify the location
to insert the remarks in the Main Member description line. If the insertion
point is less than the length of the existing information, a space
will be added to the existing Main Member description and then the
remarks will be added after that point.
Convert Push Button
The Convert push button will start the conversion process
and when complete, will present a message stating that it is complete.
This is the push button you would use to convert the data into
an EJE compatible format.

Figure 6 - Conversion Successful Window
If the output file already exist when you click on the Convert or Delimited
button, the following window will appear. You should then specify if you
wish to Append, Overwrite or Cancel the conversion process.

Figure 7 - Existing File Message Window
Delimited Push Button
The Export Text push button will export the data in a delimited
format using the tilde '~' as a delimiter between the columns. |
Example BIF (Bill Interchange Format) File |
| |
BILL
CALD_DELTATRUS
Job_name$
Job_location$
0
0.75
A325N
1
50
1
1
1AB1
1
166
166
0
ANCHOR BOLT
0
1AB1
0
0
2
5
2C1
10
1
1
0
COLUMN
0
2C1
332.732
332.732
1
1
TS5x5x1/4
A500B
213.375
2C1
277.743
277.743
M2E A500B
1
1
PL3/4x11
A36
11
pa2
22.3307
22.3307
A36
1
1
PL3/8x8 5/8
A36
9.66724
pb2
7.18907
7.18907
A36
|
2
2
PL3/8x3 1/2
A36
9
pc2
3.34983
6.69966
A36
1
1
PL3/8x3 1/2
A36
12
pd2
4.46644
4.46644
A36
1
1
PL3/8x5
A36
5
pf2
2.65859
2.65859
A36
1
1
PL3/8x3 1/2
A36
12
ph2
4.46644
4.46644
A36
1
1
PL3/8x4
A36
9
pk2
3.82838
3.82838
A36
1
1
PL3/8x3 1/2
A36
9
pm2
3.34983
3.34983
A36 |
|
Example Output E.J.E. Format File |
| |
1AB1 166 MM ANCHOR BOLT
2C1 1 MM COLUMN
2C1 1 TS 80 80 4 3414 A500 M2E A500B 1
pa2 1 PL 12 176 176 A36 1
pb2 1 PL 6 138 155 A36 1
pc2 2 PL 6 56 144 A36 1
pd2 1 PL 6 56 192 A36 1
pf2 1 PL 6 80 80 A36 1
ph2 1 PL 6 56 192 A36 1
pk2 1 PL 6 64 144 A36 1
pm2 1 PL 6 56 144 A36 1 |
Example Delimited Format File |
| |
"CALD_DELTA","Job_name$","Job_location$",0,0.75,"A325N","2","2C1",1,1,"TS5x5x1/4", " A500B",17,9,6,"2C1",
277.743,277.743,"M2E A500B","",
"CALD_DELTA","Job_name$","Job_location$",0,0.75,"A325N","2","2C1",1,1,"PL3/4x11", "A36",0,11,0,"pa2",
22.3307,22.3307,"A36","",
"CALD_DELTA","Job_name$","Job_location$",0,0.75,"A325N","2","2C1",1,1,"PL3/8x8
5/8", "A36",0,9,11,"pb2",
7.18907,7.18907,"A36","",
"CALD_DELTA","Job_name$","Job_location$",0,0.75,"A325N","2","2C1",1,2,"PL3/8x3
1/2", "A36",0,9,0,"pc2",
3.34983,6.69966,"A36","",
"CALD_DELTA","Job_name$","Job_location$",0,0.75,"A325N","2","2C1",1,1,"PL3/8x3
1/2", "A36",1,0,0,"pd2",
4.46644,4.46644,"A36","",
"CALD_DELTA","Job_name$","Job_location$",0,0.75,"A325N","2","2C1",1,1,"PL3/8x5", "A36",0,5,0,"pf2",
2.65859,2.65859,"A36","",
"CALD_DELTA","Job_name$","Job_location$",0,0.75,"A325N","2","2C1",1,1,"PL3/8x3
1/2", "A36",1,0,0,"ph2",
4.46644,4.46644,"A36","",
"CALD_DELTA","Job_name$","Job_location$",0,0.75,"A325N","2","2C1",1,1,"PL3/8x4", "A36",0,9,0,"pk2",
3.82838,3.82838,"A36","",
"CALD_DELTA","Job_name$","Job_location$",0,0.75,"A325N","2","2C1",1,1,"PL3/8x3
1/2", "A36",0,9,0,"pm2",
3.34983,3.34983,"A36","", |
| |
|
|